AISI 8620 Steel, annealed 25 mm (1 in.) round


Subcategory: AISI 8000 Series Steel; Ferrous Metal; Low Alloy Steel; Low Carbon Steel; Metal

Close Analogs: AISI 8620H

Key Words: AFNOR 22 NCD 2, UNI 20 NiCrMo 2, JIS SNCM 21 H, JIS SNCM 21, B.S. 805 H 20 (UK), B.S. 805 M 20 (UK), MIL SPEC MIL-S-16794, SAE J404, SAE J770, DIN 1.6523, AFNOR 20 NCD 2 (France), UNS G86200, AMS 6274, AMS 6276, AMS 6277, ASTM A322, ASTM A331, ASTM A505, ASTM A540

Component   Wt. %
C0.18 - 0.23 
Cr0.4 - 0.6 
Fe96.9 - 98.02 
Component   Wt. %
Mn0.7 - 0.9 
Mo0.15 - 0.25 
Ni0.4 - 0.7 
Component   Wt. %
PMax 0.035 
SMax 0.04 
Si0.15 - 0.35 

Material Notes:
Annealed: heated to 870°C, furnace cooled at 17°C/hr. to 620°C, air cooled.

Physical PropertiesMetricEnglishComments
Density7.85 g/cc0.284 lb/in³ 

Mechanical Properties
Hardness, Brinell149149 
Hardness, Knoop169169 Converted from Brinell hardness.
Hardness, Rockwell B8080 Converted from Brinell hardness.
Hardness, Vickers155155 Converted from Brinell hardness.
Tensile Strength, Ultimate540 MPa78300 psi 
Tensile Strength, Yield385 MPa55800 psi 
Elongation at Break31.3 %31.3 % in 50 mm.
Reduction of Area62.1 %62.1 % 
Modulus of Elasticity205 GPa29700 ksi Typical for steel
Bulk Modulus140 GPa20300 ksi Typical for steel
Poisson's Ratio0.290.29 Calculated
Izod Impact115 J84.8 ft-lb 
Machinability65 %65 % hot rolled and cold drawn. Based on 100% machinability for AISI 1212 steel.
Shear Modulus80 GPa11600 ksi Typical for steel.

Electrical Properties
Electrical Resistivity2.34e-005 ohm-cm2.34e-005 ohm-cm Typical steel

Thermal Properties
Specific Heat Capacity0.475 J/g-°C0.114 BTU/lb-°F Typical steel
Thermal Conductivity46.6 W/m-K323 BTU-in/hr-ft²-°F Typical steel

References for this datasheet.


Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistant format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's disclaimer and terms of use regarding this information. MatWeb data and tools provided by MatWeb, LLC.